2-2 eXtremeRAID Installation Guide
SCSI Termination
Each end of a SCSI bus must be terminated to maintain proper voltage levels
for SCSI control and data signals. The device used for this purpose is called
a terminator, and it can be built into a controller, a SCSI peripheral device, or
it can be a plug placed on the connector at the very end of a SCSI bus.
The DAC1164P controller is equipped with automatic SCSI termination
circuitry. If the controller is at the end of a SCSI bus, it automatically enables
on-board termination. The controller can also detect whether single-ended
(SE) or low-voltage differential (LVD) termination is required, and can set
the on-board termination type as needed.
If all the SCSI devices on a channel are connected either to an internal
connector of a channel, or to an external connector of a channel, the end of
the SCSI bus farthest from the DAC1164P controller must have a terminator
installed. In this case, the controller automatically enables on-board
termination. See Figure 2-1 for examples of internal or external drive
configurations.
If some SCSI devices are connected to the internal connector of a channel,
and some are connected to the external connector of the same channel, the
two ends of the SCSI bus farthest from the controller must each be
terminated. In this case, the DAC1164P controller automatically disables on-
board termination. See Figure 2-1 for an example of an internal – external
drive configuration.