Monitoring
Manual No. 771961 5-13
The following information is displayed:
• The controller model
• The firmware version residing on the controller
• The cache size
• Whether an Intelligent Battery Backup Unit is installed (N/A for not
supported on the current controller)
• The number of host ports on this controller
• The number of drive channels on the controller
• The front-end bus type (SCSI, FC-AL) of the controller
• The front-end bus width (for data transfers) and front-end bus speed
(MB/sec)
• The number of physical devices detected
• The number of logical drives configured on this controller
• Host Connection Information: HBA number, channel ID and target ID
• The status of a partner controller in a dual-active pair
• Whether the controller is set up to operate as part of a dual-active (fault
tolerant) pair
• The slot number, port number, port ID, and World Wide Name (if any)
of this specific controller
Click the Kill Partner button to cause this controller’s partner controller to be
placed in reset. The controller must be in duplex. This is required before
Expand Array.
Click the Relinquish Partner button to cause this controller’s partner
controller to return to an operating state. This is required after Expand Array
completes.
Click the Controller Options button to view a dialog box of user-definable
controller parameters (see “Setting and Modifying Controller Options” on
page 4-20).
Click the Close button to close the Controller Information window.
Comments to this Manuals