Product Description1-2 AcceleRAID Installation GuideController Features and FunctionsAcceleRAID 200 Features:• SISL to implement RAID on system board

Page 3

IntroductionManual No. 775007 1-3Operating System SupportMS-DOS 5.x, 6.x, and above are supported using drivers that reside in the AcceleRAID BIOS. Ma

Page 4 - Greetings

User-supplied Items1-4 AcceleRAID Installation GuideUser-supplied ItemsThe following user-supplied items are required to perform this installation:• C

Page 5 - About This Manual

Manual No. 775007 2-1Chapter 2Preinstallation PlanningThis chapter describes:• SCSI termination• SCSI cabling• SCSI drive preparationThere are some co

Page 6

SCSI Termination2-2 AcceleRAID Installation Guide SCSI TerminationCorrect termination is critical for the SCSI channels. Termination on the end of the

Page 7 - Contents

Preinstallation PlanningManual No. 775007 2-3Figure 2-2. System Board SCSI Termination ExamplesTInternal DriveConfigurationTSCSI Terminationon System

Page 8

AcceleRAID 250 Termination2-4 AcceleRAID Installation GuideAcceleRAID 250 TerminationThe AcceleRAID 250 is equipped with automatic SCSI termination ci

Page 9 - Introduction

Preinstallation PlanningManual No. 775007 2-5Figure 2-3. AcceleRAID 250 SCSI Termination ExamplesTAuto TerminationEnabledExternal DriveConfigurationTT

Page 10 - AcceleRAID 250 Features

SCSI Cabling2-6 AcceleRAID Installation GuideSCSI CablingAn Ultra SCSI or an Ultra2 SCSI channel supports up to 15 drives.m CautionWide and narrow SCS

Page 11 - Standard Package Contents

Preinstallation PlanningManual No. 775007 2-7*SCSI Trade Association (STA) Terms† The maximum number of devices allowed on a Wide Ultra SCSI bus is 8

Page 13 - Preinstallation Planning

SCSI Drive Preparation2-8 AcceleRAID Installation GuideSCSI Drive PreparationPrepare the drives for installation as follows:• Remove any terminators a

Page 14 - SCSI Termination

Manual No. 775007 3-1Chapter 3InstallationThis chapter describes:• Before you begin• Connectors and Jumpers• Safety considerations• Installing the con

Page 15 - Configuration

Connectors and Jumpers3-2 AcceleRAID Installation GuideConnectors and Jumpersm CautionAnti-static handling procedures are required. Leave the controll

Page 16 - AcceleRAID 250 Termination

InstallationManual No. 775007 3-3Installing the Controllerm CautionAnti-static handling procedures are required. Leave the controller in its anti-stat

Page 17 - Manual No. 775007 2-5

Performing a Standard Installation3-4 AcceleRAID Installation GuidePerforming a Standard Installation(AcceleRAID 250 only)Figure 3-2. Removing JP10 on

Page 18 - SCSI Cabling

InstallationManual No. 775007 3-5Figure 3-3. Plugging the AcceleRAID 250 into a Standard PCI Slot4. Set the SCSI ID on each internal drive to a unique

Page 19 - Manual No. 775007 2-7

Performing a Standard Installation3-6 AcceleRAID Installation GuideFigure 3-4. Connecting Internal and External Drives9. Connect a wide, round, 68-pin

Page 20 - SCSI Drive Preparation

InstallationManual No. 775007 3-7Performing a SCSI Interrupt Steering Logic (SISL) Installationm CautionIf an operating system or existing data reside

Page 21 - Installation

Performing a SCSI Interrupt Steering Logic (SISL) Installation3-8 AcceleRAID Installation GuideFigure 3-7. Pinout for JP1 on AcceleRAID 200/250m Cauti

Page 22 - Connectors and Jumpers

InstallationManual No. 775007 3-93. Plug the AcceleRAID card into the specially prewired SISL PCI slot. See the documentation provided with your syste

Page 23 - , WARNING

AcceleRAID™Installation Guide AcceleRAID 200AcceleRAID 250PCI to Ultra2 SCSIRAID ControllersPart Number 775007-01© Copyright 1999 Mylex Corporation.Al

Page 24 - WARNING

Performing a SCSI Interrupt Steering Logic (SISL) Installation3-10 AcceleRAID Installation Guide6. Be sure that termination power is enabled on all di

Page 25 - System Board

InstallationManual No. 775007 3-11Figure 4. AcceleRAID 250 in a Typical SISL InstallationFigure 5. AcceleRAID 200 in a Typical SISL InstallationThe ha

Page 26

Performing a SCSI Interrupt Steering Logic (SISL) Installation3-12 AcceleRAID Installation Guide

Page 27

Manual No. 775007 4-1Chapter 4Controller Start-upThis chapter describes:• Start-up procedures• BIOS options• BIOS Configuration Utility• Driver Instal

Page 28

Controller Start-up4-2 AcceleRAID Installation GuideController Start-upThe controller start-up procedure is the first step in confirming that the cont

Page 29

Controller Start-upManual No. 775007 4-3 Setting BIOS OptionsThe available BIOS options are:• BIOS disabled / enabled• CD-ROM boot disabled / disabled

Page 30

BIOS Options Sequence4-4 AcceleRAID Installation GuideEnable 8GByte or 2GByte DrivesThis setting affects how the BIOS reads the disk drives for the bo

Page 31 - Manual No. 775007 3-11

Controller Start-upManual No. 775007 4-5☛NoteIn the event that the RAID controller needs to be replaced, the current drive geometry will be restored f

Page 32

Using RAID EzAssist4-6 AcceleRAID Installation Guide☛NoteIf you want to do anything other than an automatic configuration, refer to the RAID EzAssist

Page 33 - Controller Start-up

Controller Start-upManual No. 775007 4-7Operating SystemIf an operating system is not already installed on the system, it can be installed on a system

Page 34 - BIOS Options Sequence

GreetingsThank you for purchasing the Mylex AcceleRAID™ controller. This manual describes the installation of the Mylex AcceleRAID controllers. Reques

Page 35 - Setting BIOS Options

Operating System Device Drivers4-8 AcceleRAID Installation Guide6. Change the Option ROM Scan to DISABLED. Enable Master should be set to ENABLED, and

Page 36

Controller Start-upManual No. 775007 4-9In Case of ProblemsIf problems are encountered during start-up, check the following:• Check SCSI cabling for l

Page 37 - Using RAID EzAssist

In Case of Problems4-10 AcceleRAID Installation Guide

Page 38

Manual No. 775007 A-1Appendix AAcceleRAID SpecificationsGeneral Hardware SpecificationsAcceleRAIDController DAC960PTLCPU Intel i960 RD® RISC 32-bit mi

Page 39

Environmental SpecificationsA-2 AcceleRAID Installation GuideEnvironmental Specifications Controller DAC960PTLTemperature Operating 0°C to +55°C (+32°

Page 40 - Global Array Manager (GAM)

AcceleRAID SpecificationsManual No. 775007 A-3DAC960PTL Block Diagram Figure A-1 shows the functional relationship between the Mylex AcceleRAID RAID C

Page 41 - In Case of Problems

DAC960PTL Block DiagramA-4 AcceleRAID Installation Guide

Page 42

Manual No. 775007 B-1Appendix BAcceleRAID Error MessagesError MessagesStart-up Error MessagesThe BIOS looks for any initialization message posted by t

Page 43 - AcceleRAID Specifications

Aborted InstallationB-2 AcceleRAID Installation GuideDuring the initialization, if the firmware fails to respond to the BIOS inquiry within two minute

Page 44 - Environmental Specifications

AcceleRAID Error MessagesManual No. 775007 B-3Configuration Utility (see Chapter 4). to recover from the error. For more information, refer to the Dis

Page 45 - DAC960PTL Block Diagram

About This ManualThis installation guide covers hardware set-up and configuration procedures necessary for the installation of Mylex AcceleRAID PCI to

Page 46

System Reboot or Power DownB-4 AcceleRAID Installation Guide

Page 47 - AcceleRAID Error Messages

Manual No. 775007 C-1Appendix CEnclosure ManagementIntroductionMylex’s AcceleRAID controllers support the industry standard enclosure management proto

Page 48 - Aborted Installation

SAF-TEC-2 AcceleRAID Installation Guide

Page 49 - System Reboot or Power Down

Manual No. 775007 D-1Appendix DRegulatory InformationClass B ComplianceTHIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE

Page 50

D-2 AcceleRAID Installation GuideDeclaration of ConformityManufacturer’s Name: Mylex CorporationManufacturer’s Address: 34551 Ardenwood Blvd.Fremont,

Page 51 - Enclosure Management

Regulatory InformationManual No. 775007 D-3Declaration of ConformityPer 89\336\EECResponsible PartyName: Mylex CorporationAddress: 34551 Ardenwood Bou

Page 52

D-4 AcceleRAID Installation GuideCommunity of EuropeCE mark is rated for the AcceleRAID as follows: CISPR 22 Radiated EmissionEN55022, EN5082-1 Generi

Page 53 - Regulatory Information

Regulatory InformationManual No. 775007 D-5Underwriters Laboratories Listing and Warning, WARNINGThis controller is furnished with a nonvolatile RAM (

Page 54 - Declaration of Conformity

D-6 AcceleRAID Installation Guide

Page 55

Manual No. 775007 G-1GlossaryCacheController memory used to speed up data transfer to and from a disk.Cache FlushRefers to an operation where all unwr

Page 57

G-2 AcceleRAID Installation GuideDisk Media Error Management DAC960 controllers transparently manage SCSI disk media errors. Disks are programmed to r

Page 58

GlossaryManual No. 775007 G-3Hot Replacement of Disks (Hot Swap)The design of the DAC960 Series controllers allows for the replacement of failed hard

Page 59 - Glossary

G-4 AcceleRAID Installation GuideOffline: A Logical Drive is in an “offline” state if...No data can be read from it or written to it.System commands

Page 60 - Drive Groups (or Drive Packs)

GlossaryManual No. 775007 G-5PCIPeripheral Component Interconnect – This is a high-performance, backplane interface, expansion slot architecture that

Page 61 - Logical Drive States

G-6 AcceleRAID Installation GuideLevel 0+1. Combines RAID 0 striping and RAID 1 mirroring. This level provides redundancy through mirroring. (Mylex R

Page 62 - Mirroring

GlossaryManual No. 775007 G-7SCSISCSI is an acronym for “Small Computer Systems Interface,” although it is often used in large systems. The SCSI inter

Page 63 - Manual No. 775007 G-5

G-8 AcceleRAID Installation GuideStandby: A SCSI disk drive is in a “standby” state if it...Is powered on; andIs able to operate properly; andWas NOT

Page 64 - Rotated XOR Redundancy

GlossaryManual No. 775007 G-9Standard Disk DriveThis term refers to a hard disk drive with SCSI, IDE, or other interface, that is attached to the host

Page 65 - SCSI Drive States

G-10 AcceleRAID Installation GuideStripe OrderThe order in which SCSI disk drives appear within a drive group. This order must be maintained, and is c

Page 66 - Segment Size

GlossaryManual No. 775007 G-11Ultra SCSIUltra SCSI, or Fast 20 SCSI is a high performance SCSI protocol that has a bus speed of 20 MegaBytes per secon

Page 67 - Standard Disk Drive

Manual No. 775007 vContentsChapter 1IntroductionProduct Description ...1-1Con

Page 68

G-12 AcceleRAID Installation Guide

Page 69 - Write Through Cache

DAC960 Problem ReportThis DPR form has been included with your Mylex product as a convenience to both you and our Technical Services Department. If

Page 71 - DAC960 Problem Report

Mylex Warranty - Customer PolicyThank you for purchasing this Mylex product for your computer system. In addition to this high-quality product,your pu

Page 72

Returned Merchandise ProceduresIf you suspect that there is a defect in the material or workmanship of this PRODUCT, you should contact the per-son or

Page 74

CorporateOffices●●●34551 Ardenwood Blvd., Fremont, CA94555-3607, USATel:510.796.6100 SalesFax:510.745.8016 www.mylex.comEuropeanSales●●

Page 75

vi AcceleRAID Installation GuideAppendix AAcceleRAID SpecificationsGeneral Hardware Specifications ....

Page 76

Manual No. 775007 1-1Chapter 1IntroductionThis chapter describes:• Product description• Standard package contents• User supplied itemsFigure 1-1. Acce

Comments to this Manuals

No comments